1,Can Aliwei IAD support H323, SIP and MGCP at the same time, same interface?
2, Can I configure any interface to run any service?
3,Can I register, send calls to fqdn or only IPs?
4,Is stun or outbound proxy for SIP supported?
5, How to configure FXO detecte BusyTone 450/350 0/350
6, How to config busyTone
7, How to config RingBackTone
8, How to change ringing?
9, How to adjust gain and solve echo (pdf)
10, How long the line from fxs ports to phone set.
11, for SIP: which softswitch Aliwei digital gateway are sure to work with.
12, for SS7 : which switches Aliwei digital gateway have tested or worked with.
13, Does Aliwei IAD support Pulse dialing?
14, IAD EIA20X Configuration examples:
EIA20X FXS configuration example (pdf)
EIA20X FXO configuration example (pdf)
EIA20X FXS/FXO configuration example (pdf)
EIA20X PPPoE configuration example (pdf)
Aliwei IAD work with
Asterisk configuration example(pdf)
1 , Commonly Aliwei IAD support three protocols, If customer like to use three protocols at the same time. It is needed to upgrade a new version.
2 , Aliwei IAD can support these protocols, customer can configure according the need.
3 , Aliwei IAD s upport both of them, for example:
<1>by ip
sip-ua
ip local 13.1.11 .22registrar ipv4:209.188.239.106
mode through
ring-mode ring-mode-183
<2>by fqdn
sip-ua
ip local 13.1.11.23
registrar dns:sipx.company.com
mode through
ring-mode ring-mode-183
4 , Support out -bound-proxy. For example:
sip-ua
ip local 13.1.11.23
registrar ipv4:209.188.239.106
mode through
out-bound-proxy ipv4:209.188.239.106
ring-mode ring-mode-183
out-bound-proxy also can be configured as out-bound-proxy dns:sipx.company.com
5 ,
Config at voice-port mode
busytone 425 200 200
busytone frequency/ RingOnTime/ RingOffTime
6 ,
config at global configuration mode
busy = 425/200 0/200
tone-generate busy f1 425 f 2 0 f 3 0 f 4 0 on-time 200 off-time 200 numCad 1 repCounter 0 on_time_2 0 off_time_2 0 on_time_3 0 off_time_3 0 tonePwr1 20 tonePwr2 20 tonePwr3 20 tonePwr4 20 7,
RingBackTone
config at global configuration mode
ringback = 425/1500 0/3000
tone-generate ring-back f1 425 f 2 0 f 3 0 f 4 0 on-time 1500 off-time 3000 numCad 1 repCounter 0 on_time_2 0 off_time_2 0 on_time_3 0 off_time_3 0 tonePwr1 20 tonePwr2 20 tonePwr3 20 tonePwr4 20
8,
config at the voice-port mode
commands:
ring-mode frequence <ringing frequency> default is 25Hz
ring-off <RingOffTime> defaut is 4000ms
ring-on <RingOnTime> default is 1000ms
voltage <Ringing voltage> default is 90V
wave <Ringing wave> default is Sine wave>
Press ? and get the range value.
10, Normally, the line phone from fxs ports to phone set is 3 to 5 km . It is needed to add a driver if the customer need more long line.
11, Cisco, H uawei, ZTE, Bell , Alcatel etc.
12, Cisco, Huawei, Alcatel, Nortel, lucent etc.
13, Yes, Aliwei IAD have software version can support pulse dialing
|